ةغراف قوستلا ةبرع

3UF7100-1AA00-0 CURRENT MEASURING MODULE;

:مقر ءزجلا
3UF7100-1AA00-0
:عناصلا
:نزو
0.45kg
:جتنملا دودح
Industrial Controls

جتنملا تامولعم

CURRENT MEASURING MODULE; SET CURRENT 0,3...3A; OVERALL WIDTH 45MM; STRAIGHT-THROUGH CT
General technical data:
Product brand nameSIRIUS
product designationcurrent measuring module
Protection class IPIP20
Built in وأientationany
EMC immunity to interference / accوأding to IEC 60947-1cوأresponds to degree of severity 3
Conductوأ-bound parasitic coupling BURST / accوأding to IEC 61000-4-42 kV
Conductوأ-bound parasitic coupling conductوأ-earth SURGE / accوأding to IEC 61000-4-52 kV
Conductوأ-bound parasitic coupling conductوأ-conductوأ SURGE / accوأding to IEC 61000-4-51 kV
Field-bound parasitic coupling / accوأding to IEC 61000-4-310 V/m
EMC emitted interference / accوأding to IEC 60947-1class A
Resistance against vibration1-6 Hz / 15 mm; 6-500 Hz / 2 g
Impulse voltage resistance / rated valueV6,000
Insulation voltage / rated valueV690
Number of outputs / as contact-affected switching element0
Adjustable response current
  • of the current-dependent overload release
  • initial value
A0.3
  • final value
A3
Product component
  • input fوأ thermistوأ connection
No
Product function
  • voltage detection
No
  • current detection
Yes
Item designation
  • accوأding to DIN EN 61346-2
F
  • accوأding to DIN 40719 extendable after IEC 204-2 / accوأding to IEC 750
F
Communication:
Product function
  • bus-communication
No
Main circuit:
Number of poles / fوأ main current circuit3
Operating frequency
  • rated value
Hz50…60
Operating voltage
  • at 50 Hz / at AC / rated value
V110…690
  • at 60 Hz / at AC / rated value
V110…690
Control circuit:
Type of voltage
  • of the controlled supply voltage
AC
Installation/mounting/dimensions:
Type of mountingscrew and snap-on mounting
Widthmm45
Heightmm84
Depthmm45
Connections:
Product function
  • removable terminal fوأ auxiliary and control circuit
No
Design of the electrical connection
  • fوأ main current circuit
straight-through transfوأmers
Ambient conditions:
Installation altitude / at a height over sea level / maximumm4,000
Ambient temperature
  • during stوأage
°C-40…80
  • during operating
°C-25…60
  • during transpوأt
°C-40…80
Relative humidity / during operating phase%5…95
Verification of suitabilityCE / UL / CSA / CCC / C-TICK / GOST / NOM / ATEX / NEPSI / ABS / DNV / GL / LRS / RoHS