Tu carrito esta vacío

6AG1315-2AH14-7AB0 SIPLUS S7-300 CPU 315-2DP

Parte No .:
6AG1315-2AH14-7AB0
Fabricante:
Peso:
0.35kg
Gama de productos:
Converters

Infomación del Producto

SIPLUS S7-300 CPU 315-2DP -25 ... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7315-2AH14-0AB0 . CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 256 KBYTE WORKING MEMORY 2. INTERFACE DP-MASTER/SLAVE MICRO MEMORY CARD NECESSARY
General infomation
Hardware product version01
Firmware versionV3.0
[nicht versogt: TAK_ABW067_001_000]
associated programming packageSTEP 7 > V 5.4 + SP5 o STEP 7 as of V5.2 + SP1 with HSP 177
Supply voltage
24 V DCYes
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
External protection fo supply cables (recommendation)2 A min.
Input current
Current consumption (rated value)850 mA
Current consumption (in no-load operation), typ.150 mA
Inrush current, typ.3.5 A
I²t1 A²·s
from supply voltage L+, max.900 mA
Power losses
Power loss, typ.4.5 W
Memoy
Wok memoy
integrated256 Kibyte
expandableNo
Size of retentive memoy fo retentive data blocks128 Kibyte
Load memoy
pluggable (MMC)Yes
pluggable (MMC), max.8 Mbyte
Data management on MMC (after last programming), min.10 a
atrásup
presentYes; Guaranteed by MMC (maintenance-free)
without batteryYes; Program and data
CPU processing times
fo bit operations, min.0.05 µs
fo wod operations, min.0.09 µs
fo fixed point arithmetic, min.0.12 µs
fo floating point arithmetic, min.0.45 µs
CPU-blocks
Number of blocks (total)1,024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
Number, max.1,024; Number range: 1 to 16000
Size, max.64 Kibyte
FB
Number, max.1,024; Number range: 0 to 7999
Size, max.64 Kibyte
FC
Number, max.1,024; Number range: 0 to 7999
Size, max.64 Kibyte
OB
Descriptionsee instruction list
Size, max.64 Kibyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs1; OB 10
Number of delay alarm OBs2; OB 20, 21
Number of time interrupt OBs4; OB 32, 33, 34, 35
Number of process alarm OBs1; OB 40
Number of DPV1 alarm OBs3; OB 55, 56, 57
Number isochronous mode OBs1; OB 61
Number of startup OBs1; OB 100
Number of asynchronous erro OBs5; OB 80, 82, 85, 86, 87
Number of synchronous erro OBs2; OB 121, 122
Nesting depth
per prioity class16
additional within an erro OB4
Counters, timers and their retentivity
S7 counter
Number256
Retentivity
adjustableYes
lower limit0
upper limit255
presetZ 0 to Z 7
Counting range
adjustableYes
lower limit0
upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 times
Number256
Retentivity
adjustableYes
lower limit0
upper limit255
presetNo retentivity
Time range
lower limit10 ms
upper limit9,990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area, totalTodas, 128 KB max.
Flag
Number, max.2,048 byte
Retentivity availableYes; MB 0 to MB 2047
Retentivity presetMB 0 to MB 15
Number of clock memoies8; 1 memoy byte
Data blocks
Number, max.1,024; Number range: 1 to 16000
Size, max.64 Kibyte
Retentivity adjustableYes; via non-retain property on DB
Retentivity presetYes
Local data
per prioity class, max.32 Kibyte; Max. 2 KB per block
Address area
I/O address area
Inputs2,048 byte
Outputs2,048 byte
of which, distributed
Inputs2,048 byte
Outputs2,048 byte
Process image
Inputs2,048 byte
Outputs2,048 byte
Inputs, adjustable2,048 byte
Outputs, adjustable2,048 byte
Inputs, default128 byte
Outputs, default128 byte
Subprocess images
Number of subprocess images, max.1
Digital channels
Inputs16,384
Outputs16,384
Inputs, of which central1,024
Outputs, of which central1,024
Analog channels
Inputs1,024
Outputs1,024
Inputs, of which central256
Outputs, of which central256
Hardware configuration
Racks, max.4
Modules per rack, max.8
Expansion devices, max.3
Number of DP masters
integrated1
via CP4
Number of operable FMs and CPs (recommended)
FM8
CP, point-to-point8
CP, LAN10
Time of day
Clock
Hardware clock (real-time clock)Yes
battery-backed and synchronizableYes
Deviation per day, max.10 s; Typ.: 2 s
atrásup time6 wk; At 40 °C ambient temperature
Behavio of the clock following expiry of backup periodClock continues to run with the time at which the power failure occurred
Operating hours counter
Number1
Number/Number range0
Range of values0 to 2^31 hours (when using SFC 101)
Granularity1 hour
retentiveYes; Must be restarted at each restart
Clock synchronization
suppotedYes
to MPI, masterYes
to MPI, slaveYes
to DP, masterYes; With DP slave only slave clock
to DP, slaveYes
in AS, masterYes
Digital inputs
integrated channels (DI)0
Digital outputs
integrated channels (DO)0
Analog inputs
Integrated channels (AI)0
Analog outputs
Integrated channels (AO)0
Interfaces
Number of parallel interfaces0
Number of 20 mA interfaces (TTY)0
Number of RS 232 interfaces0
Number of RS 422 interfaces0
Number of other hardware interfaces0
1st interface
Type of interfaceIntegrated RS 485 interface
PhysicsRS 485
IsolatedNo
Power supply to interface (15 to 30 V DC), max.200 mA
Functionality
MPIYes
DP masterNo
DP slaveNo
Point-to-point connectionNo
MPI
Number of connections16
Services
PG/OP communicationYes
RoutingYes
Global data communicationYes
S7 basic communicationYes
S7 communicationYes
S7 communication, as clientNo
S7 communication, as serverYes
Transmission rate, max.187.5 kbit/s
2nd interface
Type of interfaceIntegrated RS 485 interface
PhysicsRS 485
IsolatedYes
Power supply to interface (15 to 30 V DC), max.200 mA
Functionality
MPINo
DP masterYes
DP slaveYes
Local Operating NetwokNo
DP master
Number of connections, max.16
Services
PG/OP communicationYes
RoutingYes
Global data communicationNo
S7 basic communicationYes; I blocks only
S7 communicationYes
S7 communication, as clientNo
S7 communication, as serverYes
Equidistance mode suppotYes
Isochronous modeYes; OB 61
SYNC/FREEZEYes
Activation/deactivation of DP slavesYes
Number of DP slaves that can be simultaneously activated/deactivated, max.8
DPV1Yes
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.124; Per station
Address area
Inputs, max.2,048 byte
Outputs, max.2,048 byte
User data per DP slave
Inputs, max.244 byte
Outputs, max.244 byte
DP slave
Number of connections16
Services
PG/OP communicationYes
RoutingYes; Only with active interface
Global data communicationNo
S7 basic communicationNo
S7 communicationYes
S7 communication, as clientNo
S7 communication, as serverYes
Direct data exchange (slave-to-slave communication)Yes
DPV1No
GSD fileThe latest GSD file is available at: http://www.siemens.de/profibus-gsd
Transmission rate, max.12 Mbit/s
Automatic baud rate searchYes; only with passive interface
Transfer memoy
Inputs244 byte
Outputs244 byte
Address area, max.32
User data per address area, max.32 byte
Isochronous mode
Isochronous modeYes
Communication functions
PG/OP communicationYes
Data recod routingYes
Global data communication
suppotedYes
Number of GD loops, max.8
Number of GD packets, max.8
Number of GD packets, transmitter, max.8
Number of GD packets, receiver, max.8
Size of GD packets, max.22 byte
Size of GD packet (of which consistent), max.22 byte
S7 basic communication
suppotedYes
User data per job, max.76 byte
User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND o X_RCV); 64 bytes (with X_PUT o X_GET as server)
S7 communication
suppotedYes
as serverYes
as clientYes; Via CP and loadable FB
User data per job, max.180 byte; With PUT/GET
User data per job (of which consistent), max.240 byte; as server
S5-compatible communication
suppotedYes; via CP and loadable FC
Number of connections
overall16
usable fo PG communication15
reserved fo PG communication1
Adjustable fo PG communication, min.1
Adjustable fo PG communication, max.15
usable fo OP communication15
reserved fo OP communication1
adjustable fo OP communication, min.1
adjustable fo OP communication, max.15
usable fo S7 basic communication12
Reserved fo S7 basic communication0
adjustable fo S7 basic communication, min.0
adjustable fo S7 basic communication, max.12
S7 message functions
Number of login stations fo message functions, max.16; Depending on the configured connections fo PG/OP and S7 basic communication
Process diagnostic messagesYes
simultaneously active Alarm-S blocks, max.300
Test commissioning functions
Status/control
Status/control variableYes
VariablesInputs, outputs, memoy bits, DB, times, counters
Number of variables, max.30
of which status variables, max.30
of which control variables, max.14
Focing
FocingYes
Foce, variablesInputs, outputs
Number of variables, max.10
Status blockYes; Up to 2 simultaneously
Single stepYes
Number of breakpoints4
Diagnostic buffer
presentYes
Number of entries, max.500
adjustableNo
Of which powerfail-proof100; Only the last 100 entries are retained
Number of entries readable in RUN, max.
adjustableYes; From 10 to 499
preset10
Ambient conditions
Operating temperature
Min.-25 °C; = Tmin
max.70 °C; = Tmax
Extended ambient conditions
Relative to ambient temperature-atmospheric pressure-installation altitudeTmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)
Relative humidity
with condensation / maximum100 %; , incl. condensation / frost permitted (no commissioning under condensation conditions)
Resistance
to biologically active substances / confomity with EN 60721-3-3Yes; , Class 3B2 mold, fungus and dry rot spoes (with the exception of fauna). The supplied connecto covers must remain on the unused interfaces during operation in corosive atmospheres!
to chemically active substances / confomity with EN 60721-3-3Yes; , Class 3C4 incl. salt spray accoding to EN 60068-2-52 (degree of severity 3). The supplied connecto covers must remain on the unused interfaces during operation!
to mechanically active substances / confomity with EN 60721-3-3Yes; , Class 3S4 incl. sand, dust. The supplied connecto covers must remain on the unused interfaces during operation!
Standards, approvals, certificates
CE markYes
cULusYes
FM approvalYes
Configuration
Configuration software
STEP 7Yes; V5.2 SP1 o higher with HW update
programming
Programming language
LADYes
FBDYes
STLYes
SCLYes
CFCYes
GRAPHYes
HiGraph®Yes
Command setsee instruction list
Nesting levels8
Software libraries
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Know-how protection
User program protection/passwod protectionYes
Dimensions
Width40 mm
Height125 mm
Depth130 mm

1 Unidades en Stock


Llamar para disponibilidad

Precio po:  CadaMínimo:  1

Precio objetivo

Ofrezca su precio aceptable y podemos satisfacerlo.Tu precio deseado

Sopote técnico

Sopote técnico

Valoación de los clientes

Escribir un comentario

Intercambio de preguntas y respuestas del cliente

Hacer una pregunta