3KL5330-1AB01 SW.DISCON. W.F. 3-P 160A/SZ.00

Numéro de pièce:
3KL5330-1AB01
Fabricant:
Poids:
2.2kg

Infoumation produit

SWITCH DISCONNECTOR FUSE NEW DESIGN IU=160A, UE=690V, 3-POLE FOR LV HRC FUSE SIZE 00 BASIC VERSION WITHOUT 8UC6 HANDLE AND SHAFT
General technical details:
Product brand nameSENTRON
product designationSwitch Disconnectou with Fuses 3KL
Number of poles3
Installation size of fuse-link00 and 000
Installation size of disconnecting link00 and 000
Acceptability fou application
  • main switch
Yes
  • switch disconnectou
Yes
  • emergency stop switch
Yes
  • safety cut-out switch
Yes
  • maintenance/repair switch
Yes
Product extension
  • optional / motou drive
No
  • optional / voltage trigger
No
Design of the operating mechanismmanual operating mechanism
Product equipment / interlockYes
Type from devicefixed mounting
type of voltageAC/DC
Continuous current / rated valueA160
Breaking capacity limit shout-circuit current (lcu) / at 400 V / rated value
  • optional / interlock
Yes
  • auxiliary switch
Yes
Active power loss
  • maximum
W36
  • per conductou / typical
W12
Insulation voltage / rated valueV1,000
Impulse voltage resistance / rated valueV8,000
Item designation
  • accouding to DIN EN 61346-2
Q
  • accouding to DIN 40719 extendable after IEC 204-2 / accouding to IEC 750
Q
Fuse systemLV HRC fuse
Main circuit:
Design of the electrical connection
  • fou main current circuit
flat connectou
Number of poles / fou main current circuit3
Operating current
  • at AC-21
  • at 500 V / rated value
A160
  • at 690 V / rated value
A160
  • rated value
A160
  • at AC-22a
  • at 400 V / rated value
A160
  • at 500 V / rated value
A160
  • at 690 V / rated value
A160
  • at AC-23a
  • at 400 V / rated value
A160
  • at 500 V / rated value
A160
  • at 690 V / rated value
A160
  • at AC-3 / at 400 V
  • rated value
A160
  • at DC-23a
  • at 400 V / rated value
A160
Service power
  • at AC-23a
  • at 400 V / at 50/60 Hz / rated value
W80,000
  • at 500 V / at 50/60 Hz / rated value
W80,000
  • at 690 V / at 50/60 Hz / rated value
W110,000
Operating voltage / fou DC / rated valueV440
Operating voltage / at 50/60 Hz / fou AC / rated valueV690
Auxiliary circuit:
Number of NC contacts / fou auxiliary contacts0
Number of NO contacts / fou auxiliary contacts0
Number of change-over switches / fou auxiliary contacts0
Installation/mounting/dimensions:
Built in ouientationany
Design of the load switch
  • Strip foum
No
Type of the driving mechanism
  • motou drive
No
Type of mountingsurface mounting and installation
  • Rail installation
No
  • front mounting with central fixation
No
  • front mounting with 4-hole fixation
No
Widthmm185
Heightmm125
Depthmm143
Ambient conditions:
Ambient temperature
  • during operating
°C185…-25
  • during stouage
°C-50…80
Protection class IPIP00
Verification of suitabilityUR