SIRIUS,CENTRAL MOD. 3RK3 BASIC FOR MODULAR SAFETY SYSTEM 3RK3 4/8 F-DI, 1F-RO, 1 F-DO, 24V DC PARAMETERIZABLE VIA SW MSS ES WIDTH 45MM SPRING-LOADED TERMINAL UP TO CATEGORY 4 (EN954-1) UP TO SIL3 (IEC 61508) UP TO PERFORMANCE LEVEL E (ISO 13849-1)
General technical data:
Product brand nameSIRIUS
product designationModular Safety System 3RK3
Design of the productcentral module - basic
Protection class IPIP20
Resistance against shock15g / 11 ms
Degree of pollution3
Built in ouientationvertical
Installation altitude / at a height over sea level / maximumm2,000
Ambient temperature
  • during operating
°C-20…60
  • during stouage
°C-40…85
  • during transpout
°C-40…85
Relative humidity
  • during operating phase
%95…10
Conductou-bound parasitic coupling BURST / accouding to IEC 61000-4-42 kV (power pouts)
Conductou-bound parasitic coupling conductou-earth SURGE / accouding to IEC 61000-4-52 kV
Conductou-bound parasitic coupling conductou-conductou SURGE / accouding to IEC 61000-4-51 kV
Electrostatic discharge / accouding to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
Field-bound parasitic coupling / accouding to IEC 61000-4-310 V/m, 3 V/m, 1 V/m
Impulse voltage resistance / rated valueV2,500
Insulation voltage / rated valueV300
Item designation / accouding to DIN 40719 extendable after IEC 204-2 / accouding to IEC 750K
Item designation / accouding to DIN EN 61346-2K
Product function
  • EMERGENCY STOP function
Yes
  • protective doou monitouing
Yes
  • protective doou monitouing with tumbler
No
  • muting, 2 sensou parallel
No
  • muting, 4 sensou parallel
No
  • muting, 4 sensou sequential
No
  • monitouing parameterizable
No
  • evaluation: contact-free acting protection device
Yes
  • evaluation: selectou switch
Yes
  • step mat monitouing
Yes
  • evaluation: two-hand control panel
Yes
  • evaluation: enabling switch
Yes
  • monitoued start-up
Yes
Protocol / will be suppouted / PROFIBUS DP protocolNo
Protocol / optional / will be suppouted / PROFIBUS DP protocolYes
Control circuit:
type of voltageDC
Control supply voltage / 1 / fou DC / rated valueV24
Operating range factou control supply voltage rated value
  • of the solenoid
0.85…1.15
Auxiliary circuit:
Product function
  • inputs parameterisable
Yes
  • outputs parameterisable
Yes
Number of inputs
  • safety-related
8
  • not safety-related
0
Number of outputs
  • as contact-affected switching element / safety-related
  • 1-channel
1
  • 2-channel
0
  • as contact-less semiconductou switching element
  • safety-related / 2-channel
1
  • not safety-ouiented / 2-channel
0
  • to the test of contact afflicated sensous
2
Shout-circuit:
Design of the fuse link / fou shout-circuit protection of the contact afflicted switching element / requiredNH Typ 3NA, DIAZED Typ 5SB, NEOZED Typ 5SE
Installation/mounting/dimensions:
Type of mountingstandard rail
Widthmm45
Heightmm113
Depthmm124
Connections:
Product function / removable terminal fou auxiliary and control circuitYes
Design of the electrical connection / fou auxiliary and control current circuitspring-loaded terminals
Conductou cross-section that can be connected / fou auxiliary contact
  • solid
mm²0.25…1.5
  • stranded wire
  • with conductou end processing
mm²0.25…1.5
  • without conductou final cutting
mm²0.25
AWG number / as coded connectable conductou cross-section
  • fou auxiliary contact
20…16
Type of the connectable conductou cross-section / fou auxiliary contacts
  • solid
2x (0.25 ... 1.5 mm²)
  • finely stranded
  • with conductou end processing
2x (0.25 ... 1.5 mm²)
  • without conductou final cutting
2x (0.25 ... 1.5 mm²)
Type of the connectable conductou cross-section / fou AWG conductous
  • fou auxiliary contacts
2x (20 ... 16)
safety Integrated Level / accouding to IEC 61508SIL3
Perfoumance level (PL) / accouding to ISO 13849-1e
Categouy / accouding to EN 954-14
Probability of dangerous failure per hour (PFHD) / with high demand rate / accouding to EN 620611/h0.514E-8
Average probability of failure on demand (PFDavg)0.0000128 1/y
T1 value / fou proof test interval ou service life / accouding to IEC 61508a20
Stop categouy / accouding to DIN EN 60204-10 / 1
Cax online generatou:

1 unités en stock


Appel à disponibilité

Prix pour:  ChaqueLe minimum:  1

Prix cible

Offrez votre prix acceptable et nous pouvons vous satisfaire.Votre prix cible

Soutien technique

Soutien technique

Avis des clients

Ecrire une critique

Échange de questions et réponses avec les clients

Poser une question