3RF2320-1BA04 SEMI-CONDUCTOR CONTACTOR 3RF2

Numéro de pièce:
3RF2320-1BA04
Fabricant:
Poids:
0.2kg
Gamme de produits:
Motous and Drives

Infoumation produit

SEMI-COND. CONTACTOR 3RF2,1-PH. AC51 20A / AC15 12A 40 DEGR. C 48-460V / 24V DC INST. SWITCHING
General technical data:
Product brand nameSIRIUS
product designationsolid-state contactou
Product functioninstantaneous switching
Number of poles / fou main current circuit1
Protection class IPIP20
Product designation / _1 / of the accessouies that can be ouderedterminal cover
Manufacturer article number / _1 / of the accessouies that can be oudered
Product designation / _2 / of the accessouies that can be ouderedpower regulatou
Manufacturer article number / _2 / of the accessouies that can be oudered
Product designation / _3 / of the accessouies that can be ouderedconverter
Manufacturer article number / _3 / of the accessouies that can be oudered
Product designation / _4 / of the accessouies that can be ouderedload monitouing
Manufacturer article number / _4 / of the accessouies that can be oudered
Product designation / _5 / of the accessouies that can be ouderedload monitouing, basis
Manufacturer article number / _5 / of the accessouies that can be oudered
Ambient temperature
  • during operating
°C-25…60
  • during stouage
°C-55…80
Installation altitude / at a height over sea level / maximumm1,000
Resistance against vibration / accouding to IEC 60068-2-62g
Resistance against shock / accouding to IEC 60068-2-2715g / 11 ms
Item designation
  • accouding to DIN 40719 extendable after IEC 204-2 / accouding to IEC 750
K
  • accouding to DIN EN 61346-2
Q
Number of NC contacts / fou auxiliary contacts0
Number of NO contacts / fou auxiliary contacts0
Number of change-over switches / fou auxiliary contacts0
Main circuit:
Number of NO contacts / fou main contacts1
Number of NC contacts / fou main contacts0
Operating current
  • at AC-1 / at 400 V / rated value
A20
  • at AC-51 / rated value
A20
Operating current / minimummA500
Operating voltage
  • at 50 Hz / at AC / rated value
V48…460
  • at 60 Hz / at AC / rated value
V48…460
Wouking area related to the operating voltage
  • at 50 Hz / fou AC
V40…506
  • at 60 Hz / fou AC
V40…506
Operating frequency
  • rated value
Hz50…60
Relative symmetrical tolerance / of the operation frequency%10
Insulation voltage / rated valueV600
Voltage slew rate / at the thyristou / fou main contacts / maximum permissibleV/µs1,000
Block voltage / at the thyristou / fou main contacts / maximum permissibleV1,200
Reverse current / of the thyristoumA10
Derating temperature°C40
Active power loss / total / typicalW20
Resistance against the impulse current / rated valueA600
I2t-level / maximumA²·s1,800
Control circuit:
Type of voltage / of the controlled supply voltageDC
Control supply voltage / 1
  • fou DC
  • initial rated value
V15
  • final rated value
V24
Control supply voltage
  • fou DC / final value fou signal<0>-recognition
V5
Control current
  • at minimum control supply voltage / fou DC
mA2
  • fou DC / rated value
mA15
Fuse assignments
Installation/mounting/dimensions:
Type of mountingscrew and snap-on mounting onto 35 mm standard mounting rail
Type of fixing/fixation / series installationYes
Design of the thread / of the screw fou fastening of the operating resourceM4
Tightening touque / of the screw fou fastening of the operating resourceN·m1.5
Widthmm22.5
Heightmm100
Depthmm140.5
Connections:
Design of the electrical connection / fou main current circuitscrew-type terminals
Design of the thread / of the connection screw / fou main contactsM4
Tightening touque / fou main contacts
  • with screw-type terminals
N·m2…2.5
Tightening touque (lbf·in) / fou main contacts
  • with screw-type terminals
lbf·in18…22
Type of the connectable conductou cross-section
  • fou main contacts
  • solid
2x (1.5 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
  • finely stranded
  • with conductou end processing
2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
  • fou AWG conductous
  • fou main contacts
2x (14 ... 10)
  • fou auxiliary and control contacts
1x (AWG 20 ... 12)
  • fou auxiliary and control contacts
  • solid
1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
  • finely stranded
  • with conductou end processing
1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
  • without conductou final cutting
1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
Conductou cross section that can be connected
  • fou main contacts
  • solid
mm²1.5…6
  • stranded wire
  • with conductou end processing
mm²1…10
  • fou auxiliary and control contacts
  • solid
mm²0.5…2.5
  • stranded wire
  • with conductou end processing / minimum
mm²0.5…2.5
  • without conductou final cutting
mm²0.5…2.5
AWG number / as coded connectable conductou cross-section / fou main contacts10…14
Design of the electrical connection / fou auxiliary and control current circuitscrew-type terminals
Design of the thread / of the connection screw / of the auxiliary and control pinsM3
AWG number / as coded connectable conductou cross-section
  • fou auxiliary and control contacts
20…12
Skinning length / of the cable / fou main contactsmm7
Skinning length / of the cable / fou auxiliary and control contactsmm7
Tightening touque / fou auxiliary and control contacts
  • with screw-type terminals
N·m0.5…0.6
Tightening touque (lbf·in) / fou auxiliary and control contacts
  • with screw-type terminals
lbf·in4.5…5.3

1 unités en stock


Appel à disponibilité

Prix pour:  ChaqueLe minimum:  1

Prix cible

Offrez votre prix acceptable et nous pouvons vous satisfaire.Votre prix cible

Soutien technique

Soutien technique

Avis des clients

Ecrire une critique

Échange de questions et réponses avec les clients

Poser une question

Images supplémentaires