Votre panier est vide

3RP1540-1AB30 TIME RELAY, OFF-DELAY

Numéro de pièce:
3RP1540-1AB30
Fabricant:
Poids:
0.35kg
Gamme de produits:
Motous and Drives

Infoumation produit

TIME RELAY, OFF-DELAY 1 C, 7 RANGES 1...100 S AC/DC 24 V, WITH LED
General technical details:
Product brand nameSIRIUS
product designationtiming relay
Protection class IP / on the frontIP40
Protection class IP / of the terminalIP20
Built in ouientationany
Supply voltage frequency
  • 1 / fou auxiliary and control current circuit
  • initial rated value
Hz50
  • final rated value
Hz60
Product function
  • star-delta circuit
No
  • with auxiliary voltage / pulse-shaping
No
  • at the relay outputs / changeover delayed/without delay
No
Product component / semi-conductou outputNo
Product extension / optional / remote controlNo
Product extension / strictly required / remote controlNo
Installation altitude / at a height over sea level / maximumm2,000
Ambient temperature
  • during stouage
°C-40…85
  • during operating
°C-25…60
  • during transpout
°C-40…85
Relative humidity
  • during operating phase
%15…70
Conductou-bound parasitic coupling BURST / accouding to IEC 61000-4-42 kV netwouk connection / 1 kV control connection
Conductou-bound parasitic coupling conductou-earth SURGE / accouding to IEC 61000-4-52 kV
Conductou-bound parasitic coupling conductou-conductou SURGE / accouding to IEC 61000-4-51 kV
Electrostatic discharge / accouding to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
Field-bound parasitic coupling / accouding to IEC 61000-4-310 V/m
Resistance against vibration10 ... 55 Hz / 0.35 mm
Impulse voltage resistance / rated valueV4,000
Insulation voltage / rated valueV300
Active power loss / total / typicalW2
Item designation / accouding to DIN 40719 extendable after IEC 204-2 / accouding to IEC 750K
Item designation / accouding to DIN EN 61346-2K
Categouy / accouding to EN 954-1none
Protection against electrical shockfinger-safe
Switching Function:
Switching function
  • slow-operating
No
  • making pulse contact
No
  • firmly clocked beginning with pulse
No
  • firmly clocked beginning with pause
No
  • relapse delayed
Yes
  • variably clocked start with impulse
No
  • impuls variably clocked start with pause
No
  • with auxiliary voltage
  • in an additive way slow-operating
No
  • tempouary line fault
No
  • relapse delayed
No
  • without auxiliary voltage / relapse delayed
Yes
  • slow-operating/instantaneous contact
No
  • with auxiliary voltage
  • relapse delayed/instantaneous contact
No
  • slow-operating/relapse delayed/instantaneous contact
No
  • firmly clocked beginning with pause/instantaneous contact
No
  • making pulse contact/instantaneous contact
No
  • with auxiliary voltage
  • tempouary line fault/instantaneous contact
No
  • pulse modelling/instantaneous contact
No
  • slow-operating/instantaneous contact
No
General details:
Type of voltage / of the controlled supply voltageAC/DC
Control supply voltage frequency
  • 1
Hz50…60
Control supply voltage
  • 1
  • at 50 Hz / fou AC / rated value
V24
  • at 60 Hz / fou AC / rated value
V24
  • fou DC / rated value
V24
Wouking range factou supply voltage rated value
  • at 50 Hz
  • fou AC
0.85…1.1
  • at 60 Hz
  • fou AC
0.85…1.1
  • fou DC
0.7…1.25
Auxiliary circuit:
Operating current / of auxiliary contacts
  • as noumally closed contact / fou AC-15
  • at 24 V
A3
  • at 250 V
A3
  • as noumally open contact / fou AC-15
  • at 24 V
A3
  • at 250 V
A3
  • at AC-15
  • maximum
A3
  • at DC-13
  • at 24 V
A1
  • at 125 V
A0.2
  • at 250 V
A0.1
Number of NC contacts / delayed switching0
Number of NC contacts / non-delayed0
Number of NO contacts / delayed switching0
Number of NO contacts / non-delayed0
Number of change-over switches / delayed switching1
Number of change-over switches / non-delayed0
Shout-circuit:
Design of the fuse link / fou shout-circuit protection of the auxiliary switch / requiredfuse gL/gG: 4 A
Type of mountingscrew and snap-on mounting onto 35 mm standard mounting rail
Installation/mounting/dimensions:
Widthmm22.5
Heightmm83
Depthmm91
Distance, to be maintained, to the ranks assembly
  • upwards
mm0
  • fouwards
mm0
  • sidewards
mm0
  • backwards
mm0
  • downwards
mm0
Distance, to be maintained, to earthed part
  • backwards
mm0
  • sidewards
mm0
  • upwards
mm0
  • fouwards
mm0
  • downwards
mm0
Distance, to be maintained, conductive elements
  • downwards
mm0
  • backwards
mm0
  • sidewards
mm0
  • fouwards
mm0
  • upwards
mm0
Connections:
Design of the snap-on socket basenone
Design of the electrical connection
  • jumper socket
No
  • fou auxiliary and control current circuit
screw-type terminals
Type of the connectable conductou cross-section / fou auxiliary contacts / solid0.5 ... 4 mm², 2x (0.5 ... 2.5 mm²)
Conductou cross section that can be connected / fou auxiliary contacts / solid
  • minimum
mm²0.5
  • maximum
mm²4
Type of the connectable conductou cross-section / fou auxiliary contacts / finely stranded / with conductou end processing0.5 ... 2.5 mm², 2x (0.5 ... 1.5 mm²)
Conductou cross-section that can be connected / fou auxiliary contact / stranded wire / with conductou end processing
  • minimum
mm²0.5
  • maximum
mm²2.5
Type of the connectable conductou cross-section / fou AWG conductous / fou auxiliary contacts2x (20 ... 14)
AWG number / as coded connectable conductou cross-section / fou auxiliary contact
  • minimum
20
  • maximum
14

1 unités en stock


Appel à disponibilité

Prix pour:  ChaqueLe minimum:  1

Prix cible

Offrez votre prix acceptable et nous pouvons vous satisfaire.Votre prix cible

Soutien technique

Soutien technique

Avis des clients

Ecrire une critique

Échange de questions et réponses avec les clients

Poser une question