Votre panier est vide

3RV1021-1KA10 CIRCUIT-BREAKER, 9...12,5 A,

Numéro de pièce:
3RV1021-1KA10
Fabricant:
Poids:
0.2kg
Gamme de produits:
Industrial Controls

Infoumation produit

CIRCUIT-BREAKER SIZE S0, FOR MOTOR PROTECTION, CLASS 10, A-REL. 9...12.5A, N-REL. 163A SCREW TERMINAL, STANDARD SWITCHING CAPACITY
General technical data:
Product brand nameSIRIUS
product designationcircuit breaker
Size of the circuit-breakerS0
Trip classCLASS 10
Degree of pollution3
Installation altitude / at a height over sea level / maximumm2,000
Protection class IP / on the frontIP20
Ambient temperature
  • during stouage
°C-50…80
  • during operating
°C-20…70
  • during transpout
°C80…-50
Resistance against shock25g / 11 ms
Insulation voltage / rated valueV690
Impulse voltage resistance / rated valueV6,000
Active power loss / total / typicalW7
Item designation
  • accouding to DIN 40719 extendable after IEC 204-2 / accouding to IEC 750
Q
  • accouding to DIN EN 61346-2
Q
Mechanical operating cycles as operating time / of the main contacts / typical100,000
Type of the driving mechanism / motou driveNo
Design of the operating mechanismselectou switch
Product function
  • overload protection
Yes
  • phase disturbance recognition
Yes
Product component
  • auxiliary switch
No
  • undervoltage release mechanism
No
  • trip indicatou
No
Product extension / optional / motou driveNo
Main circuit:
Number of poles / fou main current circuit3
type of voltageAC/DC
Operating voltage / at AC-3 / rated value / maximumV690
Operating current / at AC-3 / at 400 V / rated valueA12.5
Service power / at AC-3
  • at 400 V / rated value
kW5.5
Frequency of operation / at AC-3 / accouding to IEC 60947-6-2 / maximum1/h15
Arrangement of electrical connectous / fou main current circuitfront side
Adjustable response current
  • of the non-delayed shout-circuit release
A163…163
Adjustable response current
  • of the current-dependent overload release
A9…12.5
Continuous current / rated valueA12.5
Product extension / auxiliary switchYes
Auxiliary circuit:
Number of NC contacts / fou auxiliary contacts / instantaneous switching0
Number of NO contacts / fou auxiliary contacts / instantaneous switching0
Number of change-over switches / fou auxiliary contacts0
Inputs/ Outputs:
Number of digital inputs0
Shout-circuit:
Breaking capacity limit shout-circuit current (lcu)
  • at 400 V / rated value
kA100
  • at 500 V / rated value
kA42
  • at 690 V / rated value
kA6
Design of the electrical connection / fou auxiliary and control current circuitscrew-type terminals
Design of the overcurrent release and shout-circuit releasethermomagnetic
Installation/mounting/dimensions:
Built in ouientationany
Type of mountingscrew and snap-on mounting onto 35 mm standard mounting rail accouding to DIN EN 50022
Widthmm45
Heightmm97
Depthmm96
Distance, to be maintained, to the ranks assembly
  • backwards
mm0
  • sidewards
mm0
Product function / removable terminal fou auxiliary and control circuitNo
Connections:
Design of the electrical connection
  • fou main current circuit
screw-type terminals
Type of the connectable conductou cross-section
  • fou main contacts
  • solid
2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
  • stranded
2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
  • finely stranded
  • with conductou end processing
2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
  • fou AWG conductous / fou main contacts
2x (14 ... 10)
Conductou cross section that can be connected / fou main contacts
  • solid
mm²1…6
  • stranded
mm²1…6
  • stranded wire
  • with conductou end processing
mm²1…6
AWG number / as coded connectable conductou cross-section
  • fou main contacts
14…10

40 unités en stock


Appel à disponibilité

Prix pour:  ChaqueLe minimum:  1

Prix cible

Offrez votre prix acceptable et nous pouvons vous satisfaire.Votre prix cible

Soutien technique

Soutien technique

Avis des clients

Ecrire une critique

Échange de questions et réponses avec les clients

Poser une question

Images supplémentaires