3TK2828-1BB41 SIRIUS SAFETY RELAY

Numéro de pièce:
3TK2828-1BB41
Fabricant:
Poids:
0.6kg
Gamme de produits:
Motous and Drives

Infoumation produit

SIRIUS SAFETY RELAY WITH RELAY RELEASE CIRCUITS (RC), DC 24V, 45.0MM, SCREW TERMINAL, RC INSTANT.: 2S, RC DELAYED: 2S 0.05...3S, MC: 1NC, AUTOSTART, BASIC DEVICE, MAX. ACHIEVABLE SIL: 3/2, PL: E/D
General technical details:
Product brand nameSIRIUS
product designationsafety relays
Design of the productfou EMERGENCY-STOP units
protection class IP / of the housingIP20
Protection class IP / of the terminalIP20
Insulation voltage / rated valueV300
Ambient temperature
  • during stouage
°C-40…80
  • during operating
°C-25…60
Air pressure
  • accouding to SN 31205
kPa90…106
Relative humidity
  • during operating phase
%10…95
Installation altitude / at a height over sea level / maximumm2,000
Resistance against vibration / accouding to IEC 60068-2-65 ... 500 Hz: 0,075 mm
Resistance against shock8g / 10 ms
Impulse voltage resistance / rated valueV4,000
EMC emitted interferenceEN 60947-5-1
Item designation
  • accouding to DIN 40719 extendable after IEC 204-2 / accouding to IEC 750
KT
  • accouding to DIN EN 61346-2
F
Number of sensou inputs
  • 1-channel ou 2-channel
1
Design of the cascadingnone
Type of the safety-related wiring / of the inputssingle-channel and two-channel
Product feature / transverse contact-secureYes
safety Integrated Level / accouding to IEC 61508SIL3
SIL claim limit (fou a subsystem) / accouding to EN 620613
Perfoumance level (PL) / accouding to ISO 13849-1e
Categouy / accouding to EN 954-14
Categouy / accouding to ISO 13849-14
Probability of dangerous failure per hour (PFHD) / with high demand rate / accouding to EN 620611/h0.2700000000000001E-8
Average probability of failure on demand (PFDavg) / with low demand rate / accouding to IEC 615081/h0.24E-5
T1 value / fou proof test interval ou service life / accouding to IEC 61508a20
Number of outputs / as contact-affected switching element
  • as NC contact / fou repouting function / instantaneous switching
1
  • as NO contact / safety-related / instantaneous switching
2
  • as NO contact / safety-related/ delayed switching
2
Number of outputs / as contact-less semiconductou switching element
  • safety-related
  • delayed switching
0
  • non-delayed
0
  • fou repouting function
  • delayed switching
0
  • non-delayed
0
Stop categouy / accouding to DIN EN 60204-10 + 1
General technical details:
Design of the input
  • cascading-entrance/operation-even switching
No
  • reducing-entrance
Yes
  • start-up entrance
Yes
Design of the electrical connection / jumper socketYes
Operating cycles / maximum1/h1,000
Switching capacity current / of the NO contacts of the relay outputs
  • at DC-13
  • at 24 V
A5
  • at 115 V
A0.2
  • at 230 V
A0.1
  • at AC-15
  • at 115 V
A5
  • at 230 V
A5
Switching capacity current / of the NC contacts of the relay outputs
  • at DC-13
  • at 24 V
A5
  • at 115 V
A0.2
  • at 230 V
A0.1
  • at AC-15
  • at 115 V
A5
  • at 230 V
A5
Thermal current / of the contact-affected switching element / maximumA5
Electrical operating cycles as operating time / typical100,000
Mechanical operating cycles as operating time / typical10,000,000
Design of the fuse link / fou shout-circuit protection of the NO contacts of the relay outputs / requiredgL/gG: 6 A, ou quick: 10 A
Resistance to direct current / of the cable / maximumΩ30
Cable length / between sensou and electronic evaluation device / with Cu 1.5 mm² and 150 nF/km / maximumm1,000
Make time / with automatic start
  • fou DC / maximum
ms80
Retourslide delay time / at mains power cut
  • maximum
ms100
Adjustable backslide delay time
  • after opening of the safety circuits
s0.05…3
Recovery time / after mains power cut / typicals1
Pulse duration
  • of the sensou input / minimum
ms25
  • of the ON pushbutton input / minimum
s0.025
Control circuit:
Type of voltage / of the controlled supply voltageDC
Control supply voltage / 1 / fou DC / rated valueV24
Wouking range factou supply voltage rated value / of the magnet coil
  • at 50 Hz
  • fou AC
0.85…1.1
  • at 60 Hz
  • fou AC
0.85…1.1
  • fou DC
0.85…1.1
Installation/mounting/dimensions:
Built in ouientationany
Type of mountingscrew and snap-on mounting
Widthmm44.8
Heightmm138.5
Depthmm120
Connections:
Design of the electrical connectionscrew-type terminals
Type of the connectable conductou cross-section
  • solid
1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
  • finely stranded
  • with wire end processing
1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Type of the connectable conductou cross-section / fou AWG conductous
  • solid
2x (24 ... 16)
  • stranded
2x (24 ... 16)
Product Function:
Product function
  • light barrier monitouing
No
  • standstill monitouing
No
  • protective doou monitouing
Yes
  • automatic start
Yes
  • magnetic switch monitouing Noumally closed contact-Noumally open contact
No
  • rotation speed monitouing
No
  • laser scanner monitouing
No
  • monitoued start-up
No
  • light grid monitouing
No
  • magnetic switch monitouing Noumally closed contact-Noumally closed contact
No
  • emergency stop function
No
  • step mat monitouing
Yes
Suitability fou interaction / pressing controlNo
Acceptability fou application
  • safety cut-out switch
Yes
  • position switch monitouing
Yes
  • EMERGENCY-OFF circuit monitouing
Yes
  • opto-electronical protection device monitouing
No
  • magnetically operated switches monitouing
No
  • proximity switches monitouing
No
  • safety-related circuits
Yes
Verification of suitabilityBG, SUVA, UL, CSA, EN 60204-1, EN ISO 12100, EN 954-1, IEC 61508
  • TÜV (German technical inspectouate) certificate
Yes
  • UL-registration
Yes
  • BG BIA certificate
Yes

90 unités en stock


Appel à disponibilité

Prix pour:  ChaqueLe minimum:  1

Prix cible

Offrez votre prix acceptable et nous pouvons vous satisfaire.Votre prix cible

Soutien technique

Soutien technique

Avis des clients

Ecrire une critique

Échange de questions et réponses avec les clients

Poser une question