SIMATIC S7-400H, CPU 414H CENTRAL UNIT FOR S7-400H AND S7-400F/FH, 4 INTERFACES: 1 MPI/DP, 1 DP AND 2 FOR SYNC MODULES, 1.4 MB MEMORY (700 KB DATA/700 KB CODE)
Supply voltage
24 V DCYes
Input current
from backplane bus 5 V DC, typ.1800 A
from backplane bus 5 V DC, max.2 A
Power losses
Power loss, typ.4.5 W
Backup battery
Battery operation
Backup current, typ.550 μA
Backup current, max.1530 μA
Feeding of external backup voltage to CPU5 to 15 VDC
Memory
Work memory
integrated (for program)700 Kibyte
integrated (for data)700 Kibyte
expandableNo
Load memory
expandable FEPROMYes; with Memory Card (FLASH)
expandable FEPROM, max.64 Mbyte
integrated RAM, max.256 Kibyte
expandable RAMYes; with Memory Card (RAM)
expandable RAM, max.16 Mbyte
Backup
presentYes
with batteryYes; all data
without batteryNo
CPU processing times
for bit operations, min.0.06 μs
for word operations, min.0.06 μs
for fixed point arithmetic, min.0.06 μs
for floating point arithmetic, min.0.18 μs
CPU-blocks
DB
Number, max.4095; DB 0 reserved
Size, max.64 Kibyte
FB
Number, max.2048
Size, max.64 Kibyte
FC
Number, max.2048
Size, max.64 Kibyte
OB
Number, max.see instruction list
Size, max.64 Kibyte
Nesting depth
per priority class24
Counters, timers and their retentivity
S7 counter
Number2048
Retentivity
adjustableYes
lower limit0
upper limit2047
presetZ 0 to Z 7
Counting range
lower limit0
upper limit999
IEC counter
presentYes
TypeSFB
S7 times
Number2048
Time range
lower limit10 ms
upper limit9990 s
IEC timer
presentYes
TypeSFB
Data areas and their retentivity
Flag
Number, max.8 Kibyte
Retentivity availableYes; MB 0 to MB 8191
Retentivity presetMB 0 to MB 15
Data blocks
Number, max.4096; DB 0 reserved
Size, max.64 Kibyte
Address area
I/O address area
Inputs8 Kibyte
Outputs8 Kibyte
of which, distributed
MPI/DP interface, inputs2 Kibyte
MPI/DP interface, outputs2 Kibyte
DP interface, inputs6 Kibyte
DP interface, outputs6 Kibyte
Process image
Inputs, adjustable8 Kibyte
Outputs, adjustable8 Kibyte
Inputs, default1024 byte
Outputs, default1024 byte
Subprocess images
Number of subprocess images, max.8
Digital channels
Inputs65536
Outputs65536
Inputs, of which central65536
Outputs, of which central65536
Analog channels
Inputs4096
Outputs4096
Inputs, of which central4096
Outputs, of which central4096
Hardware configuration
Expansion devices, max.21
MulticomputingNo
Interface modules
Number of connectable IMs (total), max.6
Number of connectable IM 460s, max.6
Number of connectable IM 463s, max.6; IM 463-2
Number of DP masters
integrated2
via IM 4670
via CP10
Mixed mode IM + CP permittedNo; IM 467 cannot be used jointly with CP 443-5 Ext.
via interface module0
Number of operable FMs and CPs (recommended)
FM32; Limited by number of slots and number of connections
CP, point-to-point32; Limited by number of slots and number of connections
CP, LAN32; Limited by number of slots and number of connections
Time of day
Clock
Hardware clock (real-time clock)Yes
battery-backed and synchronizableYes
Operating hours counter
Number8
Clock synchronization
supportedYes
1st interface
PhysicsRS 485 / PROFIBUS
IsolatedYes
Functionality
MPIYes; Default setting
DP masterYes
DP slaveNo
MPI
Number of connections32
Services
PG/OP communicationYes
Global data communicationNo
S7 basic communicationNo
S7 communicationYes
S7 communication, as clientYes
S7 communication, as serverYes
Transmission rate, max.12 Mbit/s
DP master
Number of connections, max.32
Services
PG/OP communicationYes
Global data communicationNo
S7 basic communicationNo
S7 communicationNo
S7 communication, as clientNo
S7 communication, as serverNo
Equidistance mode supportNo
SYNC/FREEZENo
Activation/deactivation of DP slavesYes
Direct data exchange (slave-to-slave communication)No
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.32; Number of slots, max. 512
Address area
Inputs, max.2 Kibyte
Outputs, max.2 Kibyte
User data per DP slave
Inputs, max.244 byte
Outputs, max.244 byte
Slots, max.244
per slot, max.128 byte
2nd interface
PhysicsRS 485 / PROFIBUS
IsolatedYes
Functionality
DP masterYes; Default setting
DP slaveNo
Local Operating NetworkNo
DP master
Number of connections, max.16
Services
PG/OP communicationYes
Global data communicationNo
S7 basic communicationNo
S7 communicationNo
S7 communication, as clientNo
S7 communication, as serverNo
Equidistance mode supportNo
SYNC/FREEZENo
Activation/deactivation of DP slavesNo
Direct data exchange (slave-to-slave communication)No
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.96
Address area
Inputs, max.8 Kibyte
Outputs, max.8 Kibyte
User data per DP slave
Inputs, max.244 byte
Outputs, max.244 byte
Communication functions
PG/OP communicationYes
Global data communication
supportedNo
S7 basic communication
supportedNo
S7 communication
supportedYes
as serverYes
as clientYes
User data per job, max.64 Kibyte
S5-compatible communication
supportedYes; via CP and loadable FC
User data per job, max.8 Kibyte
Standard communication (FMS)
supportedYes; Via CP and loadable FB
User data per job, max.Dependent on CP
Number of connections
overall32
usable for PG communication
reserved for PG communication1
Adjustable for PG communication, max.0
usable for OP communication
reserved for OP communication1
adjustable for OP communication, max.0
usable for S7 basic communication
Reserved for S7 basic communication0
adjustable for S7 basic communication, max.0
usable for routing
Reserved for routing0
adjustable for routing, max.0
S7 message functions
Number of login stations for message functions, max.8
Test commissioning functions
Diagnostic buffer
presentYes
Number of entries, max.3200
adjustableYes
preset120
Configuration
Configuration software
STEP 7Yes; V5.0 SP2
programming
Programming language
LADYes
FBDYes
STLYes
SCLYes
CFCYes
GRAPHYes
HiGraph®Yes
Know-how protection
User program protection/password protectionYes
Dimensions
Width50 mm
Height290 mm
Depth219 mm
Required slots2
Weight
Weight, approx.1070 g