closed-loop control infeed/regenerative feedback module
Unit type
infeed module
function status
1
heat dissipation
internal / hose
cooling method
separate cooling
degree of protection
With internal heat dissipation: IP 20 / With hose heat dissipation: IP 20 for the electronics area and IP 54 for the heatsink in the heat dissipation area
weight / approx.
26 kg
dimension / width
300 mm
dimension / height
480 mm
dimension / depth
288 mm
infeed / type
closed-loop
connection / power connection
95 mm2 or 2 x 35 mm2
connection / power connection / cross-section / max.
95 mm²
Electrical Data
rated output / infeed
80 kW
rated output / infeed / S3-60 %
104 kW
rated output / infeed / peak power
131 kW
rated output / regenerative feedback
80 kW
rated output / regenerative feedback / peak power
131 kW
rated current In
134 A
rated current In / Input / at undervoltage
149 A
Rated current In / Output / Peak current
220 A
Input voltage
400 V 3-phase AC -10% to 480 V 3-phase AC + 6 %
output voltage
600V / 625V / 680V
power frequency / min.
50 Hz
power frequency / tolerance / min.
-10 %
power frequency / max
60 Hz
power frequency / tolerance / max
10 %
efficiency eta
0.977
charging limit
20000 µF
power factor / cos phi / sine current mode
0.98
power factor / cos phi / block current mode
0.98
power factor / cos lambda / sine current mode
0.97
power factor / cos lambda / block current mode
0.89
impedance voltage / required / maximum
3 %
Ambient Conditions
ambient temperature on operation / min.
0 °C
ambient temperature / during operation / max.
40 °C
ambient temperature / during operation / max. / with power reduction
55 °C
ambient temperature / when stored / min.
-40 °C
ambient temperature / when stored / max.
70 °C
ambient temperature / when transported / min.
-40 °C
ambient temperature / when transported / max.
70 °C
Last change:
Aug 26, 2011
Target Price
Offer your acceptable price, and we may make you satisfied.Your Target Price