|
6ES7414-4HJ04-0AB0 SIMATIC S7-400H, CPU 414H
- Weight:
- 0.358kg
Product InformationSIMATIC S7-400H, CPU 414H CENTRAL UNIT FOR S7-400H AND S7-400F/FH, 4 INTERFACES: 1 MPI/DP, 1 DP AND 2 FOR SYNC MODULES, 1.4 MB MEMORY (700 KB DATA/700 KB CODE) | Supply voltage | 24 V DC | Yes | Input current | from backplane bus 5 V DC, typ. | 1800 A | from backplane bus 5 V DC, max. | 2 A | Power losses | Power loss, typ. | 4.5 W | Backup battery | Battery operation | | Backup current, typ. | 550 μA | Backup current, max. | 1530 μA | Feeding of external backup voltage to CPU | 5 to 15 VDC | Memory | Work memory | integrated (for program) | 700 Kibyte | integrated (for data) | 700 Kibyte | expandable | No | Load memory | expandable FEPROM | Yes; with Memory Card (FLASH) | expandable FEPROM, max. | 64 Mbyte | integrated RAM, max. | 256 Kibyte | expandable RAM | Yes; with Memory Card (RAM) | expandable RAM, max. | 16 Mbyte | Backup | present | Yes | with battery | Yes; all data | without battery | No | CPU processing times | for bit operations, min. | 0.06 μs | for word operations, min. | 0.06 μs | for fixed point arithmetic, min. | 0.06 μs | for floating point arithmetic, min. | 0.18 μs | CPU-blocks | DB | Number, max. | 4095; DB 0 reserved | Size, max. | 64 Kibyte | FB | Number, max. | 2048 | Size, max. | 64 Kibyte | FC | Number, max. | 2048 | Size, max. | 64 Kibyte | OB | Number, max. | see instruction list | Size, max. | 64 Kibyte | Nesting depth | per priority class | 24 | Counters, timers and their retentivity | S7 counter | Number | 2048 | Retentivity | adjustable | Yes | lower limit | 0 | upper limit | 2047 | preset | Z 0 to Z 7 | Counting range | lower limit | 0 | upper limit | 999 | IEC counter | present | Yes | Type | SFB | S7 times | Number | 2048 | Time range | lower limit | 10 ms | upper limit | 9990 s | IEC timer | present | Yes | Type | SFB | Data areas and their retentivity | Flag | Number, max. | 8 Kibyte | Retentivity available | Yes; MB 0 to MB 8191 | Retentivity preset | MB 0 to MB 15 | Data blocks | Number, max. | 4096; DB 0 reserved | Size, max. | 64 Kibyte | Address area | I/O address area | Inputs | 8 Kibyte | Outputs | 8 Kibyte | of which, distributed | MPI/DP interface, inputs | 2 Kibyte | MPI/DP interface, outputs | 2 Kibyte | DP interface, inputs | 6 Kibyte | DP interface, outputs | 6 Kibyte | Process image | Inputs, adjustable | 8 Kibyte | Outputs, adjustable | 8 Kibyte | Inputs, default | 1024 byte | Outputs, default | 1024 byte | Subprocess images | Number of subprocess images, max. | 8 | Digital channels | Inputs | 65536 | Outputs | 65536 | Inputs, of which central | 65536 | Outputs, of which central | 65536 | Analog channels | Inputs | 4096 | Outputs | 4096 | Inputs, of which central | 4096 | Outputs, of which central | 4096 | Hardware configuration | Expansion devices, max. | 21 | Multicomputing | No | Interface modules | Number of connectable IMs (total), max. | 6 | Number of connectable IM 460s, max. | 6 | Number of connectable IM 463s, max. | 6; IM 463-2 | Number of DP masters | integrated | 2 | via IM 467 | 0 | via CP | 10 | Mixed mode IM + CP permitted | No; IM 467 cannot be used jointly with CP 443-5 Ext. | via interface module | 0 | Number of operable FMs and CPs (recommended) | FM | 32; Limited by number of slots and number of connections | CP, point-to-point | 32; Limited by number of slots and number of connections | CP, LAN | 32; Limited by number of slots and number of connections | Time of day | Clock | Hardware clock (real-time clock) | Yes | battery-backed and synchronizable | Yes | Operating hours counter | Number | 8 | Clock synchronization | supported | Yes | 1st interface | Physics | RS 485 / PROFIBUS | Isolated | Yes | Functionality | MPI | Yes; Default setting | DP master | Yes | DP slave | No | MPI | Number of connections | 32 | Services | PG/OP communication | Yes | Global data communication | No | S7 basic communication | No | S7 communication | Yes | S7 communication, as client | Yes | S7 communication, as server | Yes | Transmission rate, max. | 12 Mbit/s | DP master | Number of connections, max. | 32 | Services | PG/OP communication | Yes | Global data communication | No | S7 basic communication | No | S7 communication | No | S7 communication, as client | No | S7 communication, as server | No | Equidistance mode support | No | SYNC/FREEZE | No | Activation/deactivation of DP slaves | Yes | Direct data exchange (slave-to-slave communication) | No | Transmission rate, max. | 12 Mbit/s | Number of DP slaves, max. | 32; Number of slots, max. 512 | Address area | Inputs, max. | 2 Kibyte | Outputs, max. | 2 Kibyte | User data per DP slave | Inputs, max. | 244 byte | Outputs, max. | 244 byte | Slots, max. | 244 | per slot, max. | 128 byte | 2nd interface | Physics | RS 485 / PROFIBUS | Isolated | Yes | Functionality | DP master | Yes; Default setting | DP slave | No | Local Operating Network | No | DP master | Number of connections, max. | 16 | Services | PG/OP communication | Yes | Global data communication | No | S7 basic communication | No | S7 communication | No | S7 communication, as client | No | S7 communication, as server | No | Equidistance mode support | No | SYNC/FREEZE | No | Activation/deactivation of DP slaves | No | Direct data exchange (slave-to-slave communication) | No | Transmission rate, max. | 12 Mbit/s | Number of DP slaves, max. | 96 | Address area | Inputs, max. | 8 Kibyte | Outputs, max. | 8 Kibyte | User data per DP slave | Inputs, max. | 244 byte | Outputs, max. | 244 byte | Communication functions | PG/OP communication | Yes | Global data communication | supported | No | S7 basic communication | supported | No | S7 communication | supported | Yes | as server | Yes | as client | Yes | User data per job, max. | 64 Kibyte | S5-compatible communication | supported | Yes; via CP and loadable FC | User data per job, max. | 8 Kibyte | Standard communication (FMS) | supported | Yes; Via CP and loadable FB | User data per job, max. | Dependent on CP | Number of connections | overall | 32 | usable for PG communication | | reserved for PG communication | 1 | Adjustable for PG communication, max. | 0 | usable for OP communication | | reserved for OP communication | 1 | adjustable for OP communication, max. | 0 | usable for S7 basic communication | | Reserved for S7 basic communication | 0 | adjustable for S7 basic communication, max. | 0 | usable for routing | | Reserved for routing | 0 | adjustable for routing, max. | 0 | S7 message functions | Number of login stations for message functions, max. | 8 | Test commissioning functions | Diagnostic buffer | present | Yes | Number of entries, max. | 3200 | adjustable | Yes | preset | 120 | Configuration | Configuration software | STEP 7 | Yes; V5.0 SP2 | programming | Programming language | LAD | Yes | FBD | Yes | STL | Yes | SCL | Yes | CFC | Yes | GRAPH | Yes | HiGraph® | Yes | Know-how protection | User program protection/password protection | Yes | Dimensions | Width | 50 mm | Height | 290 mm | Depth | 219 mm | Required slots | 2 | Weight | Weight, approx. | 1070 g |
Target Price
Offer your acceptable price, and we may make you satisfied.Your Target Price
|