Your cart is empty

6FC5357-0BB34-0AA0 NCU 573.4 650MHZ 64MB 6FC5357-0BB34-0AA0

Manufacturer:
Weight:
8.5kg
Product Range:
Automation Systems

Product Information

Allgemeine Daten
product nameSINUMERIK 840D powerline NCU 573.4
unit seriesSINUMERIK 840D
processorCeleron
processor / clock frequency650000000 Hz
user memory64 MB DRAM, 4 MB SRAM
SIMATIC S7 - integratedPLC 314C-2 DP
dimension / width50 mm
dimension / height316 mm
dimension / depth207 mm
weight / approx.1.05 kg
Input voltagevia SIMODRIVE device bus
power loss36 W
mounting positionvertical
heat dissipationOpen-circuit ventilation
licenceCE, cULus
Umgebungsbedingungen
degree of protectionIP20 (with NCU box)
degree of protection / front sideIP20
degree of protection / reverse sideIP00
humidity ratingClass 3K5 condensation and icing excluded. Low air temperature 0 °C (+32 °F)
relative humidity / operation< 95% for 1h, annual average < 65%
relative humidity / storage10 ... 95%
relative humidity / conveyance10 ... 95%
relative humidity / test standardDIN EN 60068-2-1, 60068-2-2, 60068-2-14, 60068-2-30
ambient temperature / during operation / min.0 °C
ambient temperature / during operation / max.55 °C
ambient temperature / when stored / min.-20 °C
ambient temperature / when stored / max.60 °C
ambient temperature / when transported / min.-20 °C
ambient temperature / when transported / max.60 °C
temperature / temperature change / max.12 °C/h
temperature / temperature change / max. / operation10 °C/h
temperature / temperature change / max. / conveyance18 °C/h
environmental conditions / mechanical environmental conditions / vibration / operation10-58 Hz: 0,075 mm, 59-500 Hz: 9,8 m/s²
environmental conditions / mechanical environmental conditions / vibration / conveyance5-9 HZ: 3,5 mm, 9-200 Hz: 9,8 m/s²
environmental conditions / mechanical environmental conditions / vibration / test standardDIN EN 60068-2-6
environmental conditions / mechanical environmental conditions / shock resistance / operation50 m/s², 30 ms, 18 shocks
environmental conditions / mechanical environmental conditions / shock resistance / conveyance300 m/s², 6 ms, 18 shocks
environmental conditions / mechanical environmental conditions / shock resistance / Test StandardDIN EN 60068-2-27
Schnittstellen
interfacesOPI/MPI/S7-300/PROFIBUS-DP/Drive bus/Device bus/2 probes/2 handwheels/4 inputs/outputs/Link module
interfaces / PC card slotPCMCIA
interfaces / PROFIBUS-DP/MPIMPI/DP RS 485
interfaces / PROFIBUS-DP1,5Mbaud
interfaces / handwheel2 handwheels via cable distributor
interfaces / I/OsVia cable distributor
Last change:Sep 14, 2011