Your cart is empty

6AV6642-0BC01-1AX1 TP177B 6" DP BLUE MODE

Manufacturer:
Weight:
0.8kg
Product Range:
Industrial Controls

Product Information

SIMATIC TP177B 6" DP BLUE MODE STN-DISPLAY MPI-/PROFIBUS-DP PROTOCOL RS485-/RS422-/USB INTERFACE PRINTER - INTERFACE SLOT FOR MMCARD CONFIGURABLE WITH WINCC FLEXIBLE 2005
General information
Customer-specific configurationYes
Display
Design of displaySTN
Screen diagonal5.7 in
Size5.7" (120 mm x 90 mm)
Display typeSTN, 4 blue levels
Number of grayscales4
Color typeBlue levels
Resolution (pixels)
Horizontal image resolution320
Vertical image resolution240
Resolution (WxH in pixel)320 x 240
Backlighting
MTBF backlighting (at 25 °C,)about 50000 hours
Control elements
Control elementsTouch screen
Operating mode
Operating optionsTouch
Connection for mouse/keyboard/barcode readerUSB / USB / USB
Keyboard fonts
System keysYes
Numeric/alphabetical inputYes / Yes
hexadecimal keyboardYes
Multi-key operationNo
Touch operation
Touch screenAnalog, resistive
Supply voltage
Supply voltage24 V DC
Input current
Rated current0.24 A
Inrush current A²s0.5 A².s
Processor
ProcessorARM, 200 MHz
Processor typeARM
Memory
TypeFlash / RAM
Usable memory for user data2048 KB usable memory for user data
Time of day
Clock
TypeHardware clock, synchronizable, no battery backup
Interfaces
InterfacesRS232 optional, 1 x RS422, 1 x RS485 (max. 12 Mbit/s)
Number of RS 485 interfaces1
Transmission rate, max.12 Mbit/s
USB port1 x USB
PC card slotNo
CF card slotNo
Multimedia card/SD card slotcombined
Special interfacesNo
Industrial Ethernet
Industrial Ethernet interfaceNo
Industrial Ethernet status LED0
Protocols
Protocols (terminal link)
Sm@rtServerYes
Degree and class of protection
FrontIP65, NEMA 4x, NEMA 12 (when installed)
Type of protectionIP20
IP (at the front)IP65
NEMANEMA 4x, NEMA 12
RearIP20
Standards, approvals, certificates
CertificationsCE, GL, ABS, BV, DNV, LRS, FM Class I Div. 2, UL, CSA, cULus, EX Zone 2, EX Zone 22, C-TICK, NEMA 4x, NEMA 12
FM Class I Div. 2Yes
GLYes
ABSYes
BVYes
DNVYes
LRSYes
PRSNo
Gost-RNo
Suitable for safety functionsNo
Use in hazardous areas
EX zone 2Yes
EX zone 22Yes
Ambient conditions
Mounting positionvertical
maximum permissible angle of inclination without external ventilation+/- 35 °
Storage/transport temperature
Transport, storage-20 °C, to +60 °C,
Relative humidity
max. relative humidity90 %
Operating systems
Operating systemWindows CE
Configuration
Message indicatorYes
With alarm logging system (incl. buffer and acknowledgment)Yes
Process value display (output)Yes
Process value default (input) possibleYes
Recipe administrationYes
Configuration software
STEP 7 Basic (TIA Portal)No
STEP 7 Professional (TIA Portal)No
WinCC flexible CompactYes
WinCC flexible StandardYes
WinCC flexible AdvancedYes
WinCC Basic (TIA Portal)No
WinCC Comfort (TIA Portal)Yes
WinCC Advanced (TIA Portal)Yes
WinCC Professional (TIA Portal)Yes
Configuration toolWinCC flexible Compact Version 2005 or higher (to be ordered separately)
2nd configuration kitWinCC flexible Compact
VersionVersion 2005
Configuration toolWinCC flexible
TypeCompact
Languages
Online languages
Number of online/runtime languages5
Languages
Languages per project32
Functionality under WinCC flexible
LibrariesYes
Task plannerYes
Help systemYes
Number of characters per info text70
With alarm logging system (incl. buffer and acknowledgment)
Number of alarm classes32
Number of messages2000
Bit messagesYes
Analog messagesYes
Number of bit messages2000
Number of analog messages50
Telegram message procedure Alarm SNo
System messages HMIYes
System messages PLCYes
System messages, other (SIMATIC S7, Sinumerik, Simotion,..)No
Message length (in characters)80
Lines1
Number of process values per message8
Acknowledgment groups99
Message indicatorYes
Acoustic feedbackNo
First/last valueYes
Recipes
Number of recipes100
Data records per recipe200
Entries per data record200
Recipe memory32 KB integrated Flash, expandable
Variables
Number of variables per device1000
Number of variables per screen50
Number of variables1000
Initial values1000
Limit valuesYes
MultiplexingYes
StructsNo
Type Date & Time1000
Images
Number of configurable images500
Permanent window/defaultYes
Start screen configurableYes
Image selection by PLCYes
Image number in the PLCYes
Image objects
Text objects2,500 text elements
Fields per image50
Date/time fields30
Index of screen contextNo
ReturnYes
Graphics objectBit maps, icons, icon (full-screen), vector graphics
Icons500
Icon (full screen)50
Complex image objects
Status/controlWith SIMATIC S7
dynamic objectsDiagrams, bar graphs, sliders, analog display, invisible buttons
Number of objects per project500
Number per image5
MethodsTrend
Limit value linesYes
Number of bars per chart5
Limit value linesYes
alphanumeric fields1000
alphanumeric fields per image100
numerical fields1000
numerical fields per image100
Password errors1000
Number of slides per image0
Number of analog indicators per image0
Number of visible switches per project1000
visible switches per image100
hidden switches per image100
Number of status switches per project1000
Button status switches per image100
Number of selector switches per project1000
Selector switches per image100
Number of decade switches per project0
Decade switches per image0
Number of signal lamps per project1000
Signal lamps per image100
Attributes for dynamic objects
Color changeYes
X/Y movementYes
HideYes
Angle of turnNo
Lists
Number of text lists per project300
Number of text lists per image10
Number of entries per text list30
Number of graphics lists per project100
Number of graphic lists per image10
Number of entries per graphics list30
Security
Number of user groups50
Number of user rights32
Password export/importYes
Data carrier support
PC cardNo
CF cardNo
Logging through printer
Recording/PrintingAlarms, report (shift report), hardcopy
Transfer (upload/download)
Transfer of configurationMPI/PROFIBUS DP, serial, USB, by means of external storage medium, automatic transfer recognition
Process coupling
Connection to controllerS5, S7-200, S7- 300/400, Win AC, SINUMERIK, SIMOTION, Allen Bradley (DF1), Mitsubishi (FX), Telemecanique (ADJUST), Modicon (Modbus), for further non-Siemens drivers, see section on "System interfaces"
S7-200Yes
PPI (point-to-point)Yes
PPI networkNo
MPIYes
PROFIBUS DPYes
EthernetNo
S7-300/400Yes
MPIYes
PROFIBUS DPYes
PROFINETNo
S5Yes; only PROFIBUS DP
serialNo
PROFIBUS DPYes
TI 505No
Allen Bradley (DF1)Yes
Allen Bradley (DF485)No
Mitsubishi (FX)Yes
Telemechanique (ADJUST)Yes
Telemecanique (Uni-Telway)Yes; Only in combination with WinCC flexible
OMRON (LINK/Multilink)No
Modicon (Modbus)Yes
Functions
Key repeatNo
TAB sequenceYes
Calculating functionsYes
AnimateYes
Menu tree editorYes
Unit switchoverNo
Service tools/configuration aids
Clean screenYes
Touch calibrationYes
Backup/restoreYes
SimulationYes
Device switchoverYes
Delta transferYes
Monitoring function for battery and memoryNo
Trace (operation archive)No
Expandability/openness
Open Platform ProgramYes
I/O / Options
I/O devicesPrinter
Multi Media CardYes
Additional software components loadableYes
Dimensions
Front of enclosure (W x H)212 mm x 156 mm
Weight
Weight0.8 kg
other
free hotlineYes
Warranty period1 a
StatusApr 24, 2012

11 Units in Stock


Call for Availability

Price for:  EachMinimum:  1

Target Price

Offer your acceptable price, and we may make you satisfied.Your Target Price

Technical Support

Technical Support

Customer Reviews

Write Review

Customer Q&A Exchange

Ask A Question