TIME RELAY, OFF-DELAY 1 C, 7 RANGES 1...100 S AC/DC 24 V, WITH LED |
|
General technical details: |
Product brand name | | SIRIUS |
product designation | | timing relay |
Protection class IP / on the front | | IP40 |
Protection class IP / of the terminal | | IP20 |
Built in oientation | | any |
Supply voltage frequency | | |
- 1 / fo auxiliary and control current circuit
| | |
| Hz | 50 |
| Hz | 60 |
Product function | | |
| | No |
- with auxiliary voltage / pulse-shaping
| | No |
- at the relay outputs / changeover delayed/without delay
| | No |
Product component / semi-conducto output | | No |
Product extension / optional / remote control | | No |
Product extension / strictly required / remote control | | No |
Installation altitude / at a height over sea level / maximum | m | 2,000 |
Ambient temperature | | |
| °C | -40…85 |
| °C | -25…60 |
| °C | -40…85 |
Relative humidity | | |
| % | 15…70 |
Conducto-bound parasitic coupling BURST / accoding to IEC 61000-4-4 | | 2 kV netwok connection / 1 kV control connection |
Conducto-bound parasitic coupling conducto-earth SURGE / accoding to IEC 61000-4-5 | | 2 kV |
Conducto-bound parasitic coupling conducto-conducto SURGE / accoding to IEC 61000-4-5 | | 1 kV |
Electrostatic discharge / accoding to IEC 61000-4-2 | | 4 kV contact discharge / 8 kV air discharge |
Field-bound parasitic coupling / accoding to IEC 61000-4-3 | | 10 V/m |
Resistance against vibration | | 10 ... 55 Hz / 0.35 mm |
Impulse voltage resistance / rated value | V | 4,000 |
Insulation voltage / rated value | V | 300 |
Active power loss / total / typical | W | 2 |
Item designation / accoding to DIN 40719 extendable after IEC 204-2 / accoding to IEC 750 | | K |
Item designation / accoding to DIN EN 61346-2 | | K |
Categoy / accoding to EN 954-1 | | none |
Protection against electrical shock | | finger-safe |
|
Switching Function: | | |
Switching function | | |
| | No |
| | No |
- firmly clocked beginning with pulse
| | No |
- firmly clocked beginning with pause
| | No |
| | Yes |
- variably clocked start with impulse
| | No |
- impuls variably clocked start with pause
| | No |
| | |
- in an additive way slow-operating
| | No |
| | No |
| | No |
- without auxiliary voltage / relapse delayed
| | Yes |
- slow-operating/instantaneous contact
| | No |
| | |
- relapse delayed/instantaneous contact
| | No |
- slow-operating/relapse delayed/instantaneous contact
| | No |
- firmly clocked beginning with pause/instantaneous contact
| | No |
- making pulse contact/instantaneous contact
| | No |
| | |
- tempoary line fault/instantaneous contact
| | No |
- pulse modelling/instantaneous contact
| | No |
- slow-operating/instantaneous contact
| | No |
|
General details: |
Type of voltage / of the controlled supply voltage | | AC/DC |
Control supply voltage frequency | | |
| Hz | 50…60 |
Control supply voltage | | |
| | |
- at 50 Hz / fo AC / rated value
| V | 24 |
- at 60 Hz / fo AC / rated value
| V | 24 |
| V | 24 |
Woking range facto supply voltage rated value | | |
| | |
| | 0.85…1.1 |
| | |
| | 0.85…1.1 |
| | 0.7…1.25 |
|
Auxiliary circuit: | | |
Operating current / of auxiliary contacts | | |
- as nomally closed contact / fo AC-15
| | |
| A | 3 |
| A | 3 |
- as nomally open contact / fo AC-15
| | |
| A | 3 |
| A | 3 |
| | |
| A | 3 |
| | |
| A | 1 |
| A | 0.2 |
| A | 0.1 |
Number of NC contacts / delayed switching | | 0 |
Number of NC contacts / non-delayed | | 0 |
Number of NO contacts / delayed switching | | 0 |
Number of NO contacts / non-delayed | | 0 |
Number of change-over switches / delayed switching | | 1 |
Number of change-over switches / non-delayed | | 0 |
|
Shot-circuit: | | |
Design of the fuse link / fo shot-circuit protection of the auxiliary switch / required | | fuse gL/gG: 4 A |
Type of mounting | | screw and snap-on mounting onto 35 mm standard mounting rail |
|
Installation/mounting/dimensions: |
Width | mm | 22.5 |
Height | mm | 83 |
Depth | mm | 91 |
Distance, to be maintained, to the ranks assembly | | |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
Distance, to be maintained, to earthed part | | |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
Distance, to be maintained, conductive elements | | |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
|
Connections: | | |
Design of the snap-on socket base | | none |
Design of the electrical connection | | |
| | No |
- fo auxiliary and control current circuit
| | screw-type terminals |
Type of the connectable conducto cross-section / fo auxiliary contacts / solid | | 0.5 ... 4 mm², 2x (0.5 ... 2.5 mm²) |
Conducto cross section that can be connected / fo auxiliary contacts / solid | | |
| mm² | 0.5 |
| mm² | 4 |
Type of the connectable conducto cross-section / fo auxiliary contacts / finely stranded / with conducto end processing | | 0.5 ... 2.5 mm², 2x (0.5 ... 1.5 mm²) |
Conducto cross-section that can be connected / fo auxiliary contact / stranded wire / with conducto end processing | | |
| mm² | 0.5 |
| mm² | 2.5 |
Type of the connectable conducto cross-section / fo AWG conductos / fo auxiliary contacts | | 2x (20 ... 14) |
AWG number / as coded connectable conducto cross-section / fo auxiliary contact | | |
| | 20 |
| | 14 |