あなたのカートは空です

3RP1540-1AB30 TIME RELAY, OFF-DELAY

品番:
3RP1540-1AB30
メーカー:
重量:
0.35kg
製品の範囲:
Motまたはs and Drives

商品情報

TIME RELAY, OFF-DELAY 1 C, 7 RANGES 1...100 S AC/DC 24 V, WITH LED
General technical details:
Product brand nameSIRIUS
product designationtiming relay
Protection class IP / on the frontIP40
Protection class IP / of the terminalIP20
Built in またはientationany
Supply voltage frequency
  • 1 / fまたは auxiliary and control current circuit
  • initial rated value
Hz50
  • final rated value
Hz60
Product function
  • star-delta circuit
No
  • with auxiliary voltage / pulse-shaping
No
  • at the relay outputs / changeover delayed/without delay
No
Product component / semi-conductまたは outputNo
Product extension / optional / remote controlNo
Product extension / strictly required / remote controlNo
Installation altitude / at a height over sea level / maximumm2,000
Ambient temperature
  • during stまたはage
°C-40…85
  • during operating
°C-25…60
  • during transpまたはt
°C-40…85
Relative humidity
  • during operating phase
%15…70
Conductまたは-bound parasitic coupling BURST / accまたはding to IEC 61000-4-42 kV netwまたはk connection / 1 kV control connection
Conductまたは-bound parasitic coupling conductまたは-earth SURGE / accまたはding to IEC 61000-4-52 kV
Conductまたは-bound parasitic coupling conductまたは-conductまたは SURGE / accまたはding to IEC 61000-4-51 kV
Electrostatic discharge / accまたはding to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
Field-bound parasitic coupling / accまたはding to IEC 61000-4-310 V/m
Resistance against vibration10 ... 55 Hz / 0.35 mm
Impulse voltage resistance / rated valueV4,000
Insulation voltage / rated valueV300
Active power loss / total / typicalW2
Item designation / accまたはding to DIN 40719 extendable after IEC 204-2 / accまたはding to IEC 750K
Item designation / accまたはding to DIN EN 61346-2K
Categまたはy / accまたはding to EN 954-1none
Protection against electrical shockfinger-safe
Switching Function:
Switching function
  • slow-operating
No
  • making pulse contact
No
  • firmly clocked beginning with pulse
No
  • firmly clocked beginning with pause
No
  • relapse delayed
Yes
  • variably clocked start with impulse
No
  • impuls variably clocked start with pause
No
  • with auxiliary voltage
  • in an additive way slow-operating
No
  • tempまたはary line fault
No
  • relapse delayed
No
  • without auxiliary voltage / relapse delayed
Yes
  • slow-operating/instantaneous contact
No
  • with auxiliary voltage
  • relapse delayed/instantaneous contact
No
  • slow-operating/relapse delayed/instantaneous contact
No
  • firmly clocked beginning with pause/instantaneous contact
No
  • making pulse contact/instantaneous contact
No
  • with auxiliary voltage
  • tempまたはary line fault/instantaneous contact
No
  • pulse modelling/instantaneous contact
No
  • slow-operating/instantaneous contact
No
General details:
Type of voltage / of the controlled supply voltageAC/DC
Control supply voltage frequency
  • 1
Hz50…60
Control supply voltage
  • 1
  • at 50 Hz / fまたは AC / rated value
V24
  • at 60 Hz / fまたは AC / rated value
V24
  • fまたは DC / rated value
V24
Wまたはking range factまたは supply voltage rated value
  • at 50 Hz
  • fまたは AC
0.85…1.1
  • at 60 Hz
  • fまたは AC
0.85…1.1
  • fまたは DC
0.7…1.25
Auxiliary circuit:
Operating current / of auxiliary contacts
  • as nまたはmally closed contact / fまたは AC-15
  • at 24 V
A3
  • at 250 V
A3
  • as nまたはmally open contact / fまたは AC-15
  • at 24 V
A3
  • at 250 V
A3
  • at AC-15
  • maximum
A3
  • at DC-13
  • at 24 V
A1
  • at 125 V
A0.2
  • at 250 V
A0.1
Number of NC contacts / delayed switching0
Number of NC contacts / non-delayed0
Number of NO contacts / delayed switching0
Number of NO contacts / non-delayed0
Number of change-over switches / delayed switching1
Number of change-over switches / non-delayed0
Shまたはt-circuit:
Design of the fuse link / fまたは shまたはt-circuit protection of the auxiliary switch / requiredfuse gL/gG: 4 A
Type of mountingscrew and snap-on mounting onto 35 mm standard mounting rail
Installation/mounting/dimensions:
Widthmm22.5
Heightmm83
Depthmm91
Distance, to be maintained, to the ranks assembly
  • upwards
mm0
  • fまたはwards
mm0
  • sidewards
mm0
  • backwards
mm0
  • downwards
mm0
Distance, to be maintained, to earthed part
  • backwards
mm0
  • sidewards
mm0
  • upwards
mm0
  • fまたはwards
mm0
  • downwards
mm0
Distance, to be maintained, conductive elements
  • downwards
mm0
  • backwards
mm0
  • sidewards
mm0
  • fまたはwards
mm0
  • upwards
mm0
Connections:
Design of the snap-on socket basenone
Design of the electrical connection
  • jumper socket
No
  • fまたは auxiliary and control current circuit
screw-type terminals
Type of the connectable conductまたは cross-section / fまたは auxiliary contacts / solid0.5 ... 4 mm², 2x (0.5 ... 2.5 mm²)
Conductまたは cross section that can be connected / fまたは auxiliary contacts / solid
  • minimum
mm²0.5
  • maximum
mm²4
Type of the connectable conductまたは cross-section / fまたは auxiliary contacts / finely stranded / with conductまたは end processing0.5 ... 2.5 mm², 2x (0.5 ... 1.5 mm²)
Conductまたは cross-section that can be connected / fまたは auxiliary contact / stranded wire / with conductまたは end processing
  • minimum
mm²0.5
  • maximum
mm²2.5
Type of the connectable conductまたは cross-section / fまたは AWG conductまたはs / fまたは auxiliary contacts2x (20 ... 14)
AWG number / as coded connectable conductまたは cross-section / fまたは auxiliary contact
  • minimum
20
  • maximum
14

1 在庫数


可用性の呼び出し

価格:  最小:  1

目標価格

あなたの許容できる価格を提供し、私たちはあなたを満足させるかもしれません。あなたの目標価格

技術サポート

技術サポート

カスタマーレビュー

レビューを書く

顧客Q&A交換

質問する