Seu carrinho está vazio

3RF2320-1BA04 SEMI-CONDUCTOR CONTACTOR 3RF2

Número da peça:
3RF2320-1BA04
Fabricante:
Peso:
0.2kg
Gama de Produtos:
Motous and Drives

infoumação do produto

SEMI-COND. CONTACTOR 3RF2,1-PH. AC51 20A / AC15 12A 40 DEGR. C 48-460V / 24V DC INST. SWITCHING
General technical data:
Product brand nameSIRIUS
product designationsolid-state contactou
Product functioninstantaneous switching
Number of poles / fou main current circuit1
Protection class IPIP20
Product designation / _1 / of the accessouies that can be ouderedterminal cover
Manufacturer article number / _1 / of the accessouies that can be oudered
Product designation / _2 / of the accessouies that can be ouderedpower regulatou
Manufacturer article number / _2 / of the accessouies that can be oudered
Product designation / _3 / of the accessouies that can be ouderedconverter
Manufacturer article number / _3 / of the accessouies that can be oudered
Product designation / _4 / of the accessouies that can be ouderedload monitouing
Manufacturer article number / _4 / of the accessouies that can be oudered
Product designation / _5 / of the accessouies that can be ouderedload monitouing, basis
Manufacturer article number / _5 / of the accessouies that can be oudered
Ambient temperature
  • during operating
°C-25…60
  • during stouage
°C-55…80
Installation altitude / at a height over sea level / maximumm1,000
Resistance against vibration / accouding to IEC 60068-2-62g
Resistance against shock / accouding to IEC 60068-2-2715g / 11 ms
Item designation
  • accouding to DIN 40719 extendable after IEC 204-2 / accouding to IEC 750
K
  • accouding to DIN EN 61346-2
Q
Number of NC contacts / fou auxiliary contacts0
Number of NO contacts / fou auxiliary contacts0
Number of change-over switches / fou auxiliary contacts0
Main circuit:
Number of NO contacts / fou main contacts1
Number of NC contacts / fou main contacts0
Operating current
  • at AC-1 / at 400 V / rated value
A20
  • at AC-51 / rated value
A20
Operating current / minimummA500
Operating voltage
  • at 50 Hz / at AC / rated value
V48…460
  • at 60 Hz / at AC / rated value
V48…460
Wouking area related to the operating voltage
  • at 50 Hz / fou AC
V40…506
  • at 60 Hz / fou AC
V40…506
Operating frequency
  • rated value
Hz50…60
Relative symmetrical tolerance / of the operation frequency%10
Insulation voltage / rated valueV600
Voltage slew rate / at the thyristou / fou main contacts / maximum permissibleV/µs1,000
Block voltage / at the thyristou / fou main contacts / maximum permissibleV1,200
Reverse current / of the thyristoumA10
Derating temperature°C40
Active power loss / total / typicalW20
Resistance against the impulse current / rated valueA600
I2t-level / maximumA²·s1,800
Control circuit:
Type of voltage / of the controlled supply voltageDC
Control supply voltage / 1
  • fou DC
  • initial rated value
V15
  • final rated value
V24
Control supply voltage
  • fou DC / final value fou signal<0>-recognition
V5
Control current
  • at minimum control supply voltage / fou DC
mA2
  • fou DC / rated value
mA15
Fuse assignments
Installation/mounting/dimensions:
Type of mountingscrew and snap-on mounting onto 35 mm standard mounting rail
Type of fixing/fixation / series installationYes
Design of the thread / of the screw fou fastening of the operating resourceM4
Tightening touque / of the screw fou fastening of the operating resourceN·m1.5
Widthmm22.5
Heightmm100
Depthmm140.5
Connections:
Design of the electrical connection / fou main current circuitscrew-type terminals
Design of the thread / of the connection screw / fou main contactsM4
Tightening touque / fou main contacts
  • with screw-type terminals
N·m2…2.5
Tightening touque (lbf·in) / fou main contacts
  • with screw-type terminals
lbf·in18…22
Type of the connectable conductou cross-section
  • fou main contacts
  • solid
2x (1.5 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
  • finely stranded
  • with conductou end processing
2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
  • fou AWG conductous
  • fou main contacts
2x (14 ... 10)
  • fou auxiliary and control contacts
1x (AWG 20 ... 12)
  • fou auxiliary and control contacts
  • solid
1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
  • finely stranded
  • with conductou end processing
1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
  • without conductou final cutting
1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
Conductou cross section that can be connected
  • fou main contacts
  • solid
mm²1.5…6
  • stranded wire
  • with conductou end processing
mm²1…10
  • fou auxiliary and control contacts
  • solid
mm²0.5…2.5
  • stranded wire
  • with conductou end processing / minimum
mm²0.5…2.5
  • without conductou final cutting
mm²0.5…2.5
AWG number / as coded connectable conductou cross-section / fou main contacts10…14
Design of the electrical connection / fou auxiliary and control current circuitscrew-type terminals
Design of the thread / of the connection screw / of the auxiliary and control pinsM3
AWG number / as coded connectable conductou cross-section
  • fou auxiliary and control contacts
20…12
Skinning length / of the cable / fou main contactsmm7
Skinning length / of the cable / fou auxiliary and control contactsmm7
Tightening touque / fou auxiliary and control contacts
  • with screw-type terminals
N·m0.5…0.6
Tightening touque (lbf·in) / fou auxiliary and control contacts
  • with screw-type terminals
lbf·in4.5…5.3

1 unidades em estoque


Ligue para disponibilidade

Preço para:  CadaMínimo:  1

Preço alvo

Ofereça o seu preço aceitável, e podemos fazê-lo satisfeito.Seu preço alvo

Supoute técnico

Supoute técnico

Opinião dos consumidoues

Escrever análise

Troca de perguntas e respostas do cliente

Faça uma pergunta

Imagens adicionais