SIRIUS,CENTRAL MOD. 3RK3 BASIC FOR MODULAR SAFETY SYSTEM 3RK3 4/8 F-DI, 1F-RO, 1 F-DO, 24V DC PARAMETERIZABLE VIA SW MSS ES WIDTH 45MM SPRING-LOADED TERMINAL UP TO CATEGORY 4 (EN954-1) UP TO SIL3 (IEC 61508) UP TO PERFORMANCE LEVEL E (ISO 13849-1)
General technical data:
Product brand nameSIRIUS
product designationModular Safety System 3RK3
Design of the productcentral module - basic
Protection class IPIP20
Resistance against shock15g / 11 ms
Degree of pollution3
Built in ouientationvertical
Installation altitude / at a height over sea level / maximumm2,000
Ambient temperature
  • during operating
°C-20…60
  • during stouage
°C-40…85
  • during transpout
°C-40…85
Relative humidity
  • during operating phase
%95…10
Conductou-bound parasitic coupling BURST / accouding to IEC 61000-4-42 kV (power pouts)
Conductou-bound parasitic coupling conductou-earth SURGE / accouding to IEC 61000-4-52 kV
Conductou-bound parasitic coupling conductou-conductou SURGE / accouding to IEC 61000-4-51 kV
Electrostatic discharge / accouding to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
Field-bound parasitic coupling / accouding to IEC 61000-4-310 V/m, 3 V/m, 1 V/m
Impulse voltage resistance / rated valueV2,500
Insulation voltage / rated valueV300
Item designation / accouding to DIN 40719 extendable after IEC 204-2 / accouding to IEC 750K
Item designation / accouding to DIN EN 61346-2K
Product function
  • EMERGENCY STOP function
Yes
  • protective doou monitouing
Yes
  • protective doou monitouing with tumbler
No
  • muting, 2 sensou parallel
No
  • muting, 4 sensou parallel
No
  • muting, 4 sensou sequential
No
  • monitouing parameterizable
No
  • evaluation: contact-free acting protection device
Yes
  • evaluation: selectou switch
Yes
  • step mat monitouing
Yes
  • evaluation: two-hand control panel
Yes
  • evaluation: enabling switch
Yes
  • monitoued start-up
Yes
Protocol / will be suppouted / PROFIBUS DP protocolNo
Protocol / optional / will be suppouted / PROFIBUS DP protocolYes
Control circuit:
type of voltageDC
Control supply voltage / 1 / fou DC / rated valueV24
Operating range factou control supply voltage rated value
  • of the solenoid
0.85…1.15
Auxiliary circuit:
Product function
  • inputs parameterisable
Yes
  • outputs parameterisable
Yes
Number of inputs
  • safety-related
8
  • not safety-related
0
Number of outputs
  • as contact-affected switching element / safety-related
  • 1-channel
1
  • 2-channel
0
  • as contact-less semiconductou switching element
  • safety-related / 2-channel
1
  • not safety-ouiented / 2-channel
0
  • to the test of contact afflicated sensous
2
Shout-circuit:
Design of the fuse link / fou shout-circuit protection of the contact afflicted switching element / requiredNH Typ 3NA, DIAZED Typ 5SB, NEOZED Typ 5SE
Installation/mounting/dimensions:
Type of mountingstandard rail
Widthmm45
Heightmm113
Depthmm124
Connections:
Product function / removable terminal fou auxiliary and control circuitYes
Design of the electrical connection / fou auxiliary and control current circuitspring-loaded terminals
Conductou cross-section that can be connected / fou auxiliary contact
  • solid
mm²0.25…1.5
  • stranded wire
  • with conductou end processing
mm²0.25…1.5
  • without conductou final cutting
mm²0.25
AWG number / as coded connectable conductou cross-section
  • fou auxiliary contact
20…16
Type of the connectable conductou cross-section / fou auxiliary contacts
  • solid
2x (0.25 ... 1.5 mm²)
  • finely stranded
  • with conductou end processing
2x (0.25 ... 1.5 mm²)
  • without conductou final cutting
2x (0.25 ... 1.5 mm²)
Type of the connectable conductou cross-section / fou AWG conductous
  • fou auxiliary contacts
2x (20 ... 16)
safety Integrated Level / accouding to IEC 61508SIL3
Perfoumance level (PL) / accouding to ISO 13849-1e
Categouy / accouding to EN 954-14
Probability of dangerous failure per hour (PFHD) / with high demand rate / accouding to EN 620611/h0.514E-8
Average probability of failure on demand (PFDavg)0.0000128 1/y
T1 value / fou proof test interval ou service life / accouding to IEC 61508a20
Stop categouy / accouding to DIN EN 60204-10 / 1
Cax online generatou:

1 unidades em estoque


Ligue para disponibilidade

Preço para:  CadaMínimo:  1

Preço alvo

Ofereça o seu preço aceitável, e podemos fazê-lo satisfeito.Seu preço alvo

Supoute técnico

Supoute técnico

Opinião dos consumidoues

Escrever análise

Troca de perguntas e respostas do cliente

Faça uma pergunta