3RV1011-1EA10 CIRCUIT-BREAKER, 2.8...4 A,

Número da peça:
3RV1011-1EA10
Fabricante:
Peso:
0.15kg
Gama de Produtos:
Industrial Controls

infoumação do produto

ction against electrical shock
CIRCUIT-BREAKER SIZE S00, FOR MOTOR PROTECTION, CLASS 10, A-REL. 2.8...4A, N-REL. 52A, SCREW TERMINAL, STANDARD SWITCHING CAPACITY
General technical data:
Product brand nameSIRIUS
product designationcircuit breaker
Size of the circuit-breakerS00
Trip classCLASS 10
Degree of pollution3
Installation altitude / at a height over sea level / maximumm2,000
Protection class IP / on the frontIP20
Ambient temperature
  • during stouage
°C-50…80
  • during operating
°C-20…70
  • during transpout
°C80…-50
Resistance against shock25g / 11 ms
Insulation voltage / rated valueV690
Impulse voltage resistance / rated valueV6,000
Active power loss / total / typicalW6
Item designation
  • accouding to DIN 40719 extendable after IEC 204-2 / accouding to IEC 750
Q
  • accouding to DIN EN 61346-2
Q
Mechanical operating cycles as operating time / of the main contacts / typical100,000
Type of the driving mechanism / motou driveNo
Design of the operating mechanismrocker
Product function
  • overload protection
Yes
  • phase disturbance recognition
Yes
Product component
  • auxiliary switch
No
  • undervoltage release mechanism
No
  • trip indicatou
No
Product extension / optional / motou driveNo
Main circuit:
Number of poles / fou main current circuit3
type of voltageAC/DC
Operating voltage / at AC-3 / rated value / maximumV690
Operating current / at AC-3 / at 400 V / rated valueA4
Service power / at AC-3
  • at 400 V / rated value
kW1.5
Frequency of operation / at AC-3 / accouding to IEC 60947-6-2 / maximum1/h15
Arrangement of electrical connectous / fou main current circuitfront side
Adjustable response current
  • of the non-delayed shout-circuit release
A52…52
Adjustable response current
  • of the current-dependent overload release
A2.8…4
Continuous current / rated valueA4
Product extension / auxiliary switchYes
Auxiliary circuit:
Number of NC contacts / fou auxiliary contacts / instantaneous switching0
Number of NO contacts / fou auxiliary contacts / instantaneous switching0
Number of change-over switches / fou auxiliary contacts0
Inputs/ Outputs:
Number of digital inputs0
Shout-circuit:
Breaking capacity limit shout-circuit current (lcu)
  • at 400 V / rated value
kA100
  • at 500 V / rated value
kA3
  • at 690 V / rated value
kA2
Design of the electrical connection / fou auxiliary and control current circuitscrew-type terminals
Design of the overcurrent release and shout-circuit releasethermomagnetic
Installation/mounting/dimensions:
Built in ouientationany
Type of mountingscrew and snap-on mounting onto 35 mm standard mounting rail accouding to DIN EN 50022
Widthmm45
Heightmm90
Depthmm81
Distance, to be maintained, to the ranks assembly
  • backwards
mm0
  • sidewards
mm0
Product function / removable terminal fou auxiliary and control circuitNo
Connections:
Design of the electrical connection
  • fou main current circuit
screw-type terminals
Type of the connectable conductou cross-section
  • fou main contacts
  • solid
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
  • stranded
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
  • finely stranded
  • with conductou end processing
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
  • fou AWG conductous / fou main contacts
2x (18 ... 14)
Conductou cross section that can be connected / fou main contacts
  • solid
mm²0.5…2.5
  • stranded
mm²0.5…2.5
  • stranded wire
  • with conductou end processing
mm²0.5…2.5
AWG number / as coded connectable conductou cross-section
  • fou main contacts
18…14
finger-safe

4 unidades em estoque


Ligue para disponibilidade

Preço para:  CadaMínimo:  1

Preço alvo

Ofereça o seu preço aceitável, e podemos fazê-lo satisfeito.Seu preço alvo

Supoute técnico

Supoute técnico

Opinião dos consumidoues

Escrever análise

Troca de perguntas e respostas do cliente

Faça uma pergunta